The feed system operates by allowing the products to be randomly fed into an orienting tray, and through the tray movement, the tablets are oriented in an upright position and introduced into individual fill tubes. A twin shuttle system with pins always releases a single product, via a drop chute, into the blister cavity. All product contact parts are made with FDA accepted materials and are easy to clean.
The XYZ Touch Frame
The XYZ Frame is installed onto intermittent and continuous motion, high and medium speed blister machines. The frame is installed onto the machine frame of the blister packer thus allowing faster blister tool changes without removal of the feed system. The two cantilevered arms support and operate the feeder cassette change parts.
The main characteristics are:
- GMP design
- Allen Bradley PLC Controller
- Control movement for X, Y & Z axis
- Operator interface via color touch screen
- Product sweep function for difficult product feeds
- Programmable pattern for drop chute movement
- Will feed products into angled cavities
- Adjustable product agitation and vibration
Password protected operator interface for the following controls:
- Product Tray agitation sequence
- Tray vibration
- X and Y movements
- Drop chute movement (Z)
- Pin pressure
New Continuous Motion XYZ Touch Frame
Aylward's frames are now more versatile. Our Touch Frames are capable of being installed on continuous motion blister packing equipment. This feature enables the frame to continually reposition itself in an uninterrupted movement allowing the feed cycle to be constant and steady.
The Feeder Cassette
Aylward Feeders are the change parts of the total Aylward Feed System. Each feeder cassette is custom designed specifically for your product. Each cassette is guaranteed to match your configuration, whether it is a single multi-product blister.
Features Include:
Quick removal and installation of feeder cassette from feed frame without any hand tools
Toolfree breakdown and assembly of individual parts for fast, easy cleaning
All product contact parts are made from FDA accepted materials
Clean and sanitize product contact parts manually, by an industrial washer, or in an autoclave
Clearly marked individual items for speedy change of components and assembly
Aylward Feed Systems Technical Data
Please Download Aylward's Technical Data Technical Data